YUSHUNXIN · Industrial target configuration

1000kg/h リチウム電池廃棄ライン

Plan an industrial target configuration around feedstock supply, battery format, 前処理, operating schedule, site utilities and required output fractions.

The page name is retained for URL and search continuity. It does not guarantee hourly or daily output for unreviewed material.

Configuration class1000kg/h target
Planning focusIndustrial material flow
オートメーションDefined by project boundary
1000kgh Battery Processing LineProject view
1000kgh Lithium Battery Recycling Facility材料 / 出力
01 · Feedstock and project fit

Industrial scale begins with supply continuity and site integration

The original 1000kg/h page focused on scale and automation. This rebuild turns those claims into a practical industrial planning framework covering receiving, buffer capacity, インターフェース, maintenance and output handling.

Lithium Battery Disposal Line01

Supply continuity

Document contracted or forecast material supply, chemistry mix, format mix and variability. Industrial equipment should not be sized from a short-term sample alone.

1000kgh Lithium Battery Recycling Facility02

Receiving and buffer plan

Map unloading, isolation, identification, temporary storage and controlled transfer. Buffer design should reflect shift patterns and upstream variability.

1000kgh Battery Processing Line03

Automation boundary

Identify which material-handling steps, alarms, interlocks, records and interfaces must be automated. The word automated is not a complete specification.

lithium battery recycling equipment factory04

Maintenance and access

Industrial layout must include inspection, cleaning, replacement access, lifting needs and safe maintenance zones around the selected modules.

02 · Process framework

Industrial process framework

Industrial configuration is more than enlarging individual machines. Expand each stage to see the engineering questions that should be resolved before approval.

01Receiving and pre-treatment+
Lithium Battery Disposal Line

Define identification, 放電, dismantling and storage boundaries.

  • Input to confirm: 形式, 化学, condition and variation at this step.
  • Scope decision: included equipment, optional controls and customer-supplied items.
  • Acceptance point: define the handover, sampling or operating check in the approved specification.
02Controlled feeding+
1000kgh Battery Processing Line

Configure feeding and size reduction for the approved operating basis.

  • Input to confirm: 形式, 化学, condition and variation at this step.
  • Scope decision: included equipment, optional controls and customer-supplied items.
  • Acceptance point: define the handover, sampling or operating check in the approved specification.
03Multi-stage separation+
electronic waste shredding machine

Arrange suitable screening, airflow, density and magnetic modules.

  • Input to confirm: 形式, 化学, condition and variation at this step.
  • Scope decision: included equipment, optional controls and customer-supplied items.
  • Acceptance point: define the handover, sampling or operating check in the approved specification.
04Collection and monitoring+
industrial gravity separation system

Define conveying, intermediate collection, alarms and records.

  • Input to confirm: 形式, 化学, condition and variation at this step.
  • Scope decision: included equipment, optional controls and customer-supplied items.
  • Acceptance point: define the handover, sampling or operating check in the approved specification.
05Site controls+
final products

Select control modules for the proposed route and documented local needs.

  • Input to confirm: 形式, 化学, condition and variation at this step.
  • Scope decision: included equipment, optional controls and customer-supplied items.
  • Acceptance point: define the handover, sampling or operating check in the approved specification.
03 · Equipment and system boundary

Industrial configuration requires coordinated modules and interfaces

Capacity class is only one input. The system also needs balanced feeding, 分離, collection, control and site interfaces.

Lithium Battery Disposal Line01
Upstream interface

Industrial receiving flow

Define the point where customer responsibility ends and the processing line begins, including identification, ストレージ and controlled feeding.

1000kgh Battery Processing Line02
Flow stability

Controlled feeding

Buffering and feeding should match the reviewed material and planned operating schedule. The proposal should state monitoring and intervention points.

electronic waste shredding machine03
Process-dependent

Multi-stage size reduction

One or more stages may be used according to format, conditioning route and target particle state. Equipment selection follows material review.

industrial gravity separation system04
System balance

Screening and separation

Screening, airflow, density and magnetic stages are balanced as a system rather than selected independently.

final products05
Downstream interface

Collection and storage

Define containers, transfer, sampling, storage, dust control and downstream dispatch for each output category.

1000kgh Lithium Battery Recycling Facility06
Automation scope

Controls and records

The approved scope should describe alarms, interlocks, operator values, batch or shift records and interfaces with site systems.

04 · Decision detail

Industrial project decisions that should be written into the scope

A larger target configuration needs clearer ownership and interface definitions.

01

Material-flow ownership

Receiving, 放電, 解体, 餌やり, intermediate storage and output dispatch.

02

Control philosophy

Operator roles, alarms, interlocks, shutdown boundaries, data records and maintenance modes.

03

Utilities and site

Electrical standard, installed power basis, ventilation, compressed air, access and available footprint.

04

Acceptance plan

Feedstock window, test material, sampling, performance conditions and documentation owners.

05 · Technical clarification table

1000kg/h project checklist

This table separates the current planning basis from items that require material tests, site information or written human approval.

Project item Current basis Status
Configuration class 1000kg/h target Controlled
Guaranteed output Not stated on website Locked
Feedstock supply basis お客様のご意見 To confirm
Chemistry and format From material profile To confirm
運行スケジュール お客様のご意見 To confirm
Automation boundary Defined in proposal Project-dependent
公共事業 Based on site information To confirm
Material flow and layout Based on site review To confirm
06 · Output and acceptance

Design output handling as part of the line

At industrial scale, collection, sampling, storage and downstream transfer are part of system design—not an afterthought.

black mass from battery recycling01

Powder-bearing output

Confirm sealed collection, sampling, container handling and the downstream acceptance window.

final products02

Metal-bearing outputs

Copper-, アルミニウム- and ferrous-bearing fractions require defined collection and transfer points.

1000kgh Lithium Battery Recycling Facility03

Residual and recirculation streams

The proposal should identify residual material, recirculation and customer responsibilities for downstream handling.

Acceptance discipline: Yield, 純度, capacity and recovery values are not assumed from a website description. They must be tied to the approved feedstock, test basis and written project specification.

07 · Decision-stage support

Get the right response for your current decision stage

Tell YUSHUNXIN whether you are researching, testing feasibility, comparing suppliers or preparing procurement. The project brief routes the next conversation around the information you have now.

研究Clarify material and process options.
実現可能性Review tests, site and project boundary.
Supplier comparisonAlign scope and acceptance method.
調達Resolve open items for an approved proposal.
08 · Engineering communication

Why work with YUSHUNXIN

YUSHUNXIN combines equipment configuration with layout and project-input review, documenting assumptions and open items before an industrial scope is presented as final.

あ

Confirmed facts

Approved material data and project requirements are shown as the basis of the proposal.

B

Project-dependent items

Configuration choices remain conditional until the feedstock and site have been reviewed.

C

Human approval gates

Commercial terms, final performance and compliance statements require authorized review.

D

Version control

The proposal should identify the approved configuration version, assumptions and open questions.

09 · Frequently asked questions

Questions project teams ask before a proposal

Is 1000kg/h a guaranteed throughput?+

いいえ. It is the target configuration represented by the existing page. Actual performance requires written technical confirmation.

Can daily output be calculated from the page name?+

Not as a public commitment. Availability, feed consistency, maintenance and operating conditions affect actual output.

What automation is included?+

The proposal should define material handling, 監視, alarms, interlocks, records and interfaces.

Does the line meet every country’s requirements?+

No blanket statement is made. The customer and qualified local parties confirm permits and applicable local requirements.

What should an industrial brief include?+

Include supply, 化学, 形式, 前処理, 事業基盤, 出力, サイト, 公共事業, country and integration needs.

カタログに基づいたエンジニアリングベース

1,000 kg/h scope comparison

Use the 1,000 kg/h class only after defining the process modules included in the stable throughput measurement.

01

入荷素材

Representative battery mix, incoming preparation, hourly schedule and acceptance targets.

02

期待される出力

Classified electrode-, copper-, アルミニウム- and iron-bearing fractions; measured results remain test-controlled.

03

プロジェクトインターフェース

Complete safety, environmental, 公共事業, controls, storage and downstream scope.

モデルとスコープのレジスタ

Use only the row matching the selected process boundary.

カタログ参照容量力物理的エンベロープ含まれる境界
YSXパブリックファミリー公共機器ファミリー500–1,000kg/h102–238kW20–35mライン; 7.5–19.5トン標準装備ファミリーエンベロープ; モデルごとの割り当てなし
YSX-LR1000LRコンプリートライン1,000 kg/h410 kW45 × 17 × 7.5 メートルコンディショニング, 分離・ガス処理ライン
プロジェクトリファレンス - 1000以前の統合レイアウト1,000 kg/h349 kW80 × 7 × 7 メートル公開されたモデル ラベルのない以前のレイアウト

設定ルール: カタログ容量は計画の参考値です. 安定したスループット, 設置/動作電力, フットプリント, 回復, 純度, 排出量と公共需要には承認された機器リストが必要です, representative material and written acceptance conditions.

設定やお見積りの前に必要な情報

  1. 代表的な資料写真, specifications and available sample.
  2. 必要なキャパシティにシフトごとの時間数を加えたもの, shifts per day and operating days.
  3. 目標出力, sampling method and downstream receiver requirements.
  4. 拠点の国, 利用可能な電力, 燃料, 水, compressed air and building limits.
  5. 地域環境, 火, storage and occupational-safety requirements.
  6. 要求された配送境界: 装置, レイアウト, インストール, commissioning and training.