A higher-throughput PV line can add automated handling, staged size reduction, aðskilnað, environmental controls and central monitoring. Confirm the final equipment list and commercial boundary in writing.
Kostir:
- Stöðug framleiðsla sparar launakostnað;
- Snjallt eftirlitskerfi gerir kleift að fylgjast með endurheimtahraða og orkunotkun í rauntíma;
- Kælihringrásarkerfi og hávaðaminnkandi tæki eru valkvæð fyrir aðlögun að fjölbreyttu rekstrarumhverfi.
Installed power, footprint, staffing and measured recovery are released only with the approved model, representative material test and site scope.
Hverjir eru kostir okkar við þjónustu og samvinnu?
Þjónusta okkar leggur áherslu á hreina orkugeirann, bjóða viðskiptavinum sjálfbæran PV endurvinnslubúnað fyrir hreina orkuverkefni.
Complete route selection
Translate sustainability goals into a measurable mass balance, utility boundary and downstream route.
Incoming material
Module mix, target throughput, lóðarveitur, local environmental criteria and receiver requirements.
Expected outputs
Documented material fractions and residues; environmental claims require a defined calculation boundary.
Project interfaces
All line, building, utility, monitoring and downstream interfaces.
Use only the row matching the selected process boundary.
| Catalogue reference | Getu | Kraftur | Physical envelope | Included boundary |
|---|---|---|---|---|
| YSX-M1000Single-glass mechanical | 1 t/h | 277.6 kW | 36 × 6 × 6 m | Integrated mechanical line |
| YSX-TK500Tunnel thermal | 500 kg/klst | 116.65 kW | 65 × 13 × 7.5 m | Continuous tunnel thermal line |
| YSX-TK1000Tunnel thermal | 1,000 kg/klst | 126.65 kW | 72 × 13 × 7.5 m | Continuous tunnel thermal line |
| YSX-TK2000Tunnel thermal | 2,000 kg/klst | 136.65 kW | 80 × 13 × 7.5 m | Continuous tunnel thermal line |
| YSX-PF5Batch thermal | 5 t/dag | 140.45 kW | 46 × 33 × 7.5 m | Mixed-module batch thermal line |
| YSX-PF16Batch thermal | 16 t/dag | 142.45 kW | 40 × 26 × 7.5 m | Mixed-module batch thermal line |
| YSX-8000Earlier integrated thermal | 8 t/dag | Configuration controlled | 50 × 30 × 8 m | Earlier thermal project reference; reactor Φ2200 × 6000 × 20 mm |
| YSX-16000Earlier integrated thermal | 16 t/dag | Configuration controlled | 60 × 30 × 8 m | Earlier thermal project reference; reactor Φ2800 × 6600 × 18 mm |
Configuration rule: catalogue capacity is a planning reference. Stable throughput, installed/operating power, footprint, recovery, hreinleika, emissions and utility demand require the approved equipment list, representative material and written acceptance conditions.
Information required before configuration and quotation
- Representative material photos, specifications and available sample.
- Required capacity plus hours per shift, shifts per day and operating days.
- Markmið framleiðsla, sampling method and downstream receiver requirements.
- Site country, available power, fuel, vatn, compressed air and building limits.
- Local environmental, fire, storage and occupational-safety requirements.
- Requested delivery boundary: búnaði, skipulag, installation, commissioning and training.
