A higher-throughput PV line can add automated handling, staged size reduction, atskillelse, environmental controls and central monitoring. Confirm the final equipment list and commercial boundary in writing.

Continuous PV Recycling Equipment for Clean Energy Projects

Advantages:

  • Continuous production saves labor costs;
  • Intelligent monitoring system enables real-time tracking of recovery rates and energy consumption data;
  • Cooling circulation system and noise reduction devices are optional for adaptability to diverse operational environments.
Configuration-controlled performance.

Installed power, fotspor, staffing and measured recovery are released only with the approved model, representative material test and site scope.

What Are Our Services and Cooperation Advantages?

Our services focus on the clean energy sector, offering clients sustainable PV recycling equipment for clean energy projects.

KATALOG-JUSTERT INGENIØRGRUNNLAG

Complete route selection

Translate sustainability goals into a measurable mass balance, utility boundary and downstream route.

01

Innkommende materiale

Module mix, target throughput, site utilities, local environmental criteria and receiver requirements.

02

Forventede utganger

Documented material fractions and residues; environmental claims require a defined calculation boundary.

03

Prosjektgrensesnitt

All line, bygning, utility, monitoring and downstream interfaces.

MODELL OG OMFANGSREGISTRET

Bruk kun raden som samsvarer med den valgte prosessgrensen.

KatalogreferanseKapasitetMaktFysisk konvoluttInkludert grense
YSX-M1000Mekanisk enkeltglass1 t/t277.6 kW36 × 6 × 6 mIntegrert mekanisk linje
YSX-TK500Tunnel termisk500 kg/t116.65 kW65 × 13 × 7.5 mKontinuerlig tunnel termisk linje
YSX-TK1000Tunnel termisk1,000 kg/t126.65 kW72 × 13 × 7.5 mKontinuerlig tunnel termisk linje
YSX-TK2000Tunnel termisk2,000 kg/t136.65 kW80 × 13 × 7.5 mKontinuerlig tunnel termisk linje
YSX-PF5Batch termisk5 t/dag140.45 kW46 × 33 × 7.5 mBatch termisk linje med blandede moduler
YSX-PF16Batch termisk16 t/dag142.45 kW40 × 26 × 7.5 mBatch termisk linje med blandede moduler
YSX-8000Tidligere integrert termisk8 t/dagKonfigurasjonskontrollert50 × 30 × 8 mTidligere termisk prosjektreferanse; reaktor Φ2200 × 6000 × 20 mm
YSX-16000Tidligere integrert termisk16 t/dagKonfigurasjonskontrollert60 × 30 × 8 mTidligere termisk prosjektreferanse; reaktor Φ2800 × 6600 × 18 mm

Konfigurasjonsregel: katalogkapasitet er en planleggingsreferanse. Stabil gjennomstrømning, installert/driftskraft, fotspor, bedring, renhet, utslipp og bruksbehov krever godkjent utstyrsliste, representativt materiale og skriftlige akseptbetingelser.

Informasjon nødvendig før konfigurasjon og tilbud

  1. Representative materialbilder, spesifikasjoner og tilgjengelig prøve.
  2. Nødvendig kapasitet pluss timer per skift, skift per dag og driftsdager.
  3. Mål utganger, prøvetakingsmetode og nedstrøms mottakerkrav.
  4. Nettstedets land, tilgjengelig kraft, brensel, vann, trykkluft og bygningsgrenser.
  5. Lokalt miljø, ild, krav til oppbevaring og yrkessikkerhet.
  6. Forespurt leveringsgrense: utstyr, layout, installasjon, igangkjøring og opplæring.