Do not treat a reactor name or daily capacity as a complete project specification.
Matyè materyo, preparasyon, operating continuity, kondansasyon, gas safety, product handling, kontwòl anviwònman an, utilities and local delivery scope must be configured together.
Approved small-scale reference
YSX-F1 to YSX-F5 denote 1, 2, 3, 4 epi 5 t/day skid or modular planning references for tire, plastic or oily-sludge trials.
Material balance
Lwil oliv, gaz, solids and metal-bearing outputs require representative feedstock, stable-run data and an agreed sampling boundary.
Commercial boundary
Prices, operating costs, product value and return require dated quotations and local market evidence.
Source control: approved YOTO group product register. Final parameters are issued on the project-specific technical agreement.
A continuous plastic-pyrolysis project adds controlled feeding, staged condensation, gas treatment and central controls. Uptime, energy demand, output routes and price require project confirmation.
Why Choose YUSHUNXIN?
We provide not only equipment but also turnkey solutions. These encompass raw material evaluation and process design, plant layout and equipment installation, operational training and maintenance guidance, as well as long-term technical optimization and after-sales service. Whether you are a plastic recycler, solid waste management company, or energy company in the circular economy, we can tailor the most cost-effective plastic-to-fuel project solution for you.
Anplis de sa, we can provide you with numerous other waste recycling systems, tankou eco-friendly ways to turn tires into fuel, sludge waste pyrolysis plant, solisyon pwojè piroliz panèl solè, and etc. If you have any other requirements, feel free to contact us immediately!
PE-, PP- and selected PS-rich streams can follow different thermal and condensation behavior. PVC, PET, brominated plastics, medical plastics and e-waste plastics require separate assessment.

Follow the material, vapor, liquid, gas and solid paths
The reactor is one part of the line. Commercial operability depends on how each stream is prepared, transferred, controlled and discharged.
- 01Material characterization
- 02Feed preparation and sealed transfer
- 03Controlled thermal conversion
- 04Vapor separation and staged condensation
- 05Non-condensable gas safety and reuse
- 06Solid cooling, discharge and product handling
Configuration questions that change the proposal
The following points should be resolved before selecting a capacity or preparing a commercial quotation.
Polymer composition
Confirm PE, PP, PS, PVC and PET proportions instead of describing the feed simply as mixed plastic.
Halogen control
PVC and brominated additives can change corrosion, gas-cleaning and recovered-liquid requirements.
Wax management
Plastic-derived vapors and liquids may require temperature-controlled lines, insulation and condensation staging.
Product route
Define whether recovered liquid is intended for permitted fuel use, refinery feed evaluation or another locally accepted outlet.
Make utilities and product outlets visible before investment
A useful feasibility review connects the mass balance, balans enèji, operating schedule and local product route.
Operating schedule
Define planned hours per day, shutdown windows, cleaning strategy, labor model and feedstock storage capacity.
Entegrasyon enèji
Evaluate non-condensable gas reuse, startup fuel, electrical loads, cooling demand and optional downstream energy use as one balance.
Quality control
Set sampling points for incoming material, condensate fractions, recovered solids, wastewater and exhaust gas.
Commercial boundary
Budgetary results remain conditional until the feedstock, sit, product route and local compliance requirements are confirmed.
Gade fwontyè ekipman konekte.
Referans vizyèl sipòte diskisyon sou layout bonè. Ekipman final la, aranjman ak interfaces yo konfime nan materyèl pwojè a ak sit.
Tradui enfòmasyon pwojè yo nan yon lis ekipman.
Matris referans sa a montre lojik desizyon an. Kantite final yo, modèl ak interfaces fè pati pwopozisyon pwojè apwouve a.
| Blòk sistèm | Dimansyon tipik | Konfigirasyon baz |
|---|---|---|
| Polymer preparation | Klasman, dechire, drying and removal of incompatible fractions | PE, PP, PS, PVC, PET and additive profile |
| Feed and conversion | Density control, sealed transfer, reactor and heating system | Bulk density, melt behavior and operating duty |
| Wax and liquid handling | Temperature-controlled vapor lines, staged condensation and storage | Wax tendency and target recovered-liquid route |
| Halogen and gas control | Material exclusion, corrosion review and gas-treatment provisions | PVC, brominated additives and local limits |
| Residue and utilities | Solid discharge, refwadisman, water and electrical interfaces | Residue classification and site conditions |
Avanse pwojè a sèlman lè prèv ki nesesè yo disponib.
Chak pòtay vire enfòmasyon kliyan an nan yon pwodiksyon defini teknik oswa komèsyal pou pwochen desizyon an.
Polymer screen
Quantify target polymers, PVC, PET, additives, moisture and contamination.
SòtiAccepted and excluded feed specificationWout tèmik
Validate feeding, wax behavior, condensation and corrosion controls.
SòtiMaterial-specific process routeProduct and permit
Confirm recovered-product status, outlets and local environmental boundary.
SòtiCommercial and compliance evidence packConfiguration review
Freeze preparation, raktor, rekiperasyon, utilities and acceptance interfaces.
SòtiProject configuration basisKesyon pou rezoud anvan konfigirasyon.
Repons yo defini fwontyè jeni an; yo pa ranplase tès materyèl reprezantan oswa revizyon konfòmite lokal yo.
What determines the continuous pyrolysis equipment list?
Feedstock form, konpozisyon, imidite, contamination, planned operating schedule, recovered-product route, site utilities and permit requirements determine the configuration.
Can tires, plastics and oily sludge use exactly the same line?
Non. They may share thermal-conversion principles, but their preparation, feeding, corrosion, kondansasyon, solid handling and environmental controls differ materially.
Can recovered oil performance be guaranteed from a general material description?
Non. Representative analysis and an agreed sampling method are required before recovered-liquid quantity, quality or downstream use can be evaluated.
What should be included in acceptance testing?
Define feedstock, run duration, mass balance, estabilite opere, sampled outputs, sèvis piblik, safety interlocks and the applicable emissions or residue tests.
Defini materyèl la anvan ou chwazi ekipman an.
Pataje yon deskripsyon materyèl reprezantan, volim ki disponib, sitiyasyon sit ak rezilta sib. YUSHUNXIN pral sèvi ak reyalite sa yo pou prepare fwontyè pwosesis ki enpòtan ak diskisyon konfigirasyon an.